Physical
and Material Characteristics:
Corrugated metal encapsulated with chemically bonded flexible
graphite.
Nominal thickness: 1/16 inch.
Graphite layers: 2 layers, each flexible graphite nominal .020 inch
thick.
Metal inset: Nominal .024 inch thick austinetic stainless steel
with corrugations. Other types of metal are available.
Gasket Dimensions: manufactured to all Internationally Accepted
Standards and can accomodate special sizes or configurations.
Joint
Assembly Characteristics:
Gasket shall achieve tightness and be suitable for joint assembly
using the same manual procedures, skills, care and tools as is appropriate
for compressed asbestos sheet gaskets. Bolt load control such as
torque settings is optional. Torque wrench not required.
Fire Resistance:
Simulated Tightness Test (FITT):
M&P Sealing Company, certifies the result of two tests,
conducted in accordance with the Pressure Vessel Research Council
FITT procedure 1.3 (Ref.1) on NPS 4 test gaskets exposed to a 20
minute heat-up plus 15 minute soak @ 1200°F, and the following:
Required post exposure Minimum Tightness: Tpmin > 32 (Helium)
Typical post exposure Minimum Tightness: Tpmin = 2000 (Helium)
Room Temperature
Tightness (Helium Media ROTT):
M&P Sealing Company certifies the result of two or more
tests on 4 7/8" ID by 5 7/8" OD gaskets, conducted in
accordance with the Pressure Vessel Research Council developed Room
Temperature Tightness Test (ROTT) [Ref.2] procedure and the following:
|
Requirement
|
Gb
|
a
|
Gs
|
S100
|
S1,000
(1.2)
|
| |
|
Maximum:
|
1,300
|
0.273
|
9
|
3,180
|
5,630
|
|
Typical:
|
922
|
0.248
|
5
|
2,889
|
5,114
|
Notes:
(1)
The constants Gb, a and Gs shall be determined by the ROT test procedure
of Ref [2]
(2) S100 and S1000 are stresses (psi) respectively representing
the values Gb(100)ª Gb(1000)ª.
Crush
Qualification Test:
M&P Sealing Company certifies the results of a crush test
on the Graftec Gasket that indicates the tightness parameter,
Tp: and the gasket deflection, Dg (in.) with a gasket stress, Sg
(psi) up to 40,000psi and internal pressure of 800psi (Helium).
The test demonstrates adequate resistance to crushing by excessive
bolt load.
|